Rogowski coil
Named after German physicist Walter Rogowski, Rogowski is an electrical device which used to measure alternation current (AC), such as high-speed transients, pulsed currents, or power-frequency sinusoidal currents. It's no special requirements for the conductors & dimensions, with fast instantaneous response capability, which is widely used in occasions where traditional current measuring devices. The Rogowski coils with flexible type and rigid type.
The simplest way of a Rogowski coil is that a coil uniformly wound N turns per meter on a non-magnetic bobbin of constant cross-sectional area A. The winding wire returned to the staring point along the central axis of former and both ends are connected to the cable. The free end of the coil is plugged into the tee plug adjacent to the cable connection, so that the coil can surround the conductor carrying the current to be measured.
Coilcore flexible type Rogowski Coils
Advantage:
Main Application:
Item
ZXRA400
Ip
Testing Range (AC)
0.1A~100KA
Vo
Rated Output (AC)
88mv/1000A 50Hz 25°C (Customized Support)
Vi
Insulation Voltage
5KV rms/50Hz/1min L among Primary & Secondary circuits
L
Linearity
0.23%
Ta
Working Temperature
-25°C~+85°C
Ts
Storage Temperature
-40°C~+90°C
Sw
Position Sensitivity
±1.5%
Ts
Coil Size
400mm Length
Position Sensitivity
Dimension
Coilcore rigid type Rogowski Coils
Working Temperature |
-40°C~+70°C |
Storage Temperature |
-40°C~+80°C |
Working Humidity |
15%~85% RH (Non-condensing) |
Test Current Range |
1A~10kA |
Output Signal |
1A/4mV,, can be adjusted as request |
Bandwidth (-3DB) |
10Hz ~100 KHz |
Flame retardant grade |
UL94 V0 |
Environmental Certification |
ROHS |
People prefer customized Rogowski coils, to precise the best design, please kindly advise:
1. What is coil's working diameter?
2. What is the working frequency, sinal waveform, sine wave or pulse wave?
3. Current Input?
4. Current Output /Voltage Output? AC or DC?
5. Accuracy?
6. Whether with integrator?
7. Auxiliary power supply voltage is 5V, 12V, 24V DC or 220V AC?
8. Default Coil Withstand voltage is 660V, whats about yours?
Anterior :
Customized Power InductorPróxima :
Discuss about Magnetic Annealing MachineCategorías
Nuevo blog
Tel : +86-20-85649266
Fax : +86-20-85649263
Correo electrónico : derful@coilcore.com
A402 Zhuangyuangang Industry Park, No.186 Qishan Road, Tianhe District, Guangzhou 510663
© Derechos de autor: 2024 Guangzhou Amorphous Electronic Technology Co.,ltd. Reservados todos los derechos. 粤ICP备2021057165号
Red IPv6 admitida
Enlaces amistosos:
Precision Air Conditioning wellav syblecode gangyuantech PCB Board eavisionag PLC jinhuaelec kenmold 5gplc Mu Metal Core Manufacturer PLC modules liantronics Customized Filter Supplier tslcd szgilong addbuyplc ifpdtech dtechelectronics sekloadcell naturollsensor smarts-electronics bnttablesocket mbluetech esdled oscymonitor current sensor